FHIR © HL7.org  |  Server Home  |  XIG Home  |  XIG Stats  |  Server Source  |  FHIR  

FHIR IG Statistics: StructureDefinition/zib-VaccinationRecommendation

Packagenictiz.fhir.nl.stu3.zib2015
Resource TypeStructureDefinition
Idzib-VaccinationRecommendation
FHIR VersionR3
Sourcehttps://simplifier.net/resolve?scope=nictiz.fhir.nl.stu3.zib2015@1.0.0&canonical=http://nictiz.nl/fhir/StructureDefinition/zib-VaccinationRecommendation
URLhttp://nictiz.nl/fhir/StructureDefinition/zib-VaccinationRecommendation
Version1.0
Statusretired
Date2017-04-26T14:46:25.6166784+02:00
NameZIB-VaccinationRecommendation
TitleHCIM VaccinationRecommendation
Realmnl
Authorityhl7
DescriptionThis profile is one of two profile based on Vaccinatie as defined by the Dutch Health and Care Information models (Dutch: Zorginformatiebouwsteen or ZIB) version 1.0.
PurposeThe ZIB vaccinatie defines the concept DesiredDateForRevaccination. FHIR has a dedicated resources for this. To cover DesiredDateForRevaccination and to exand on the ZIB vaccination, the ImmunizationRecommendation Resource is used and profiled.
CopyrightCC0
TypeImmunizationRecommendation
Kindresource

Resources that use this resource

No resources found


Resources that this resource uses

StructureDefinition
zib-AllergyIntolerancezib AllergyIntolerance
nl-core-organizationnl-core-organization
nl-core-patientnl-core-patient
zib-VaccinationHCIM Vaccination
ValueSet
2.16.840.1.113883.2.4.3.11.60.40.2.11.1.4--20150401000000ProductCodeATCCodelijst
2.16.840.1.113883.2.4.3.11.60.40.2.11.1.3--20150401000000ProductCodeGPKCodelijst
2.16.840.1.113883.2.4.3.11.60.40.2.11.1.5--20150401000000ProductCodeGTINCodelijst
2.16.840.1.113883.2.4.3.11.60.40.2.11.1.2--20150401000000ProductCodeHPKCodelijst
2.16.840.1.113883.2.4.3.11.60.40.2.11.1.1--20150401000000ProductCodePRKCodelijst
2.16.840.1.113883.2.4.3.11.60.40.2.11.1.6--20150401000000ProductCodeZICodelijst

Narrative

No narrative content found in resource


Source

{
  "resourceType": "StructureDefinition",
  "id": "zib-VaccinationRecommendation",
  "meta": {
    "lastUpdated": "2017-04-26T15:18:37.756+02:00"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode": "pher"
    }
  ],
  "url": "http://nictiz.nl/fhir/StructureDefinition/zib-VaccinationRecommendation",
  "version": "1.0",
  "name": "ZIB-VaccinationRecommendation",
  "title": "HCIM VaccinationRecommendation",
  "status": "retired",
  "date": "2017-04-26T14:46:25.6166784+02:00",
  "publisher": "Nictiz",
  "contact": [
    {
      "name": "Nictiz",
      "telecom": [
        {
          "system": "email",
          "value": "info@nictiz.nl",
          "use": "work"
        }
      ]
    }
  ],
  "description": "This profile is one of two profile based on Vaccinatie as defined by the Dutch Health and Care Information models (Dutch: Zorginformatiebouwsteen or ZIB) version 1.0.",
  "purpose": "The ZIB vaccinatie defines the concept DesiredDateForRevaccination. FHIR has a dedicated resources for this. To cover DesiredDateForRevaccination and to exand on the ZIB vaccination, the ImmunizationRecommendation Resource is used and profiled.",
  "copyright": "CC0",
  "fhirVersion": "3.0.1",
  "mapping": [
    {
      "identity": "hcim-vaccination-v1.2-2015EN",
      "uri": "https://zibs.nl/wiki/Vaccination-v1.2(2015EN)",
      "name": "HCIM Vaccination-v1.2(2015EN)"
    },
    {
      "identity": "hcim-plannedcareactivityfortransfer-v1.2.1-2015EN",
      "uri": "https://zibs.nl/wiki/PlannedCareActivityForTransfer-v1.2.1(2015EN)",
      "name": "HCIM PlannedCareActivityForTransfer-v1.2.1(2015EN)"
    }
  ],
  "kind": "resource",
  "abstract": false,
  "type": "ImmunizationRecommendation",
  "baseDefinition": "http://hl7.org/fhir/StructureDefinition/ImmunizationRecommendation",
  "derivation": "constraint",
  "differential": {
    "element": [
      {
        "id": "ImmunizationRecommendation",
        "path": "ImmunizationRecommendation"
      },
      {
        "id": "ImmunizationRecommendation.patient",
        "path": "ImmunizationRecommendation.patient",
        "type": [
          {
            "code": "Reference",
            "targetProfile": "http://hl7.org/fhir/StructureDefinition/Patient"
          },
          {
            "code": "Reference",
            "targetProfile": "http://fhir.nl/fhir/StructureDefinition/nl-core-patient"
          }
        ]
      },
      {
        "id": "ImmunizationRecommendation.recommendation.date",
        "path": "ImmunizationRecommendation.recommendation.date",
        "short": "DesiredDateForRevaccination",
        "definition": "Date on which this vaccination will have to be repeated according to the author’s information.",
        "alias": [
          "GewensteDatumHervaccinatie"
        ],
        "mapping": [
          {
            "identity": "hcim-vaccination-v1.2-2015EN",
            "map": "NL-CM:11.1.5"
          }
        ]
      },
      {
        "id": "ImmunizationRecommendation.recommendation.vaccineCode",
        "path": "ImmunizationRecommendation.recommendation.vaccineCode",
        "short": "ProductCode",
        "definition": "The product code of the vaccine administered.\r\nThere are several possible code systems for documenting the product code. If the vaccination data is registered based on an anamnesis, coding with the ATC code is preferred. In all cases it concerns those products that fall under ATC group J07 (vaccines).",
        "alias": [
          "ProductCode"
        ],
        "mapping": [
          {
            "identity": "hcim-vaccination-v1.2-2015EN",
            "map": "NL-CM:11.1.2"
          }
        ]
      },
      {
        "id": "ImmunizationRecommendation.recommendation.vaccineCode.coding",
        "path": "ImmunizationRecommendation.recommendation.vaccineCode.coding",
        "slicing": {
          "discriminator": [
            {
              "type": "value",
              "path": "system"
            }
          ],
          "rules": "open"
        },
        "min": 1
      },
      {
        "id": "ImmunizationRecommendation.recommendation.vaccineCode.coding.GPK",
        "path": "ImmunizationRecommendation.recommendation.vaccineCode.coding",
        "sliceName": "ProductCodeGPKCodelijst",
        "max": "1",
        "binding": {
          "strength": "extensible",
          "description": "ProductCodeGPKCodelijst",
          "valueSetReference": {
            "reference": "http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.11.1.3--20150401000000",
            "display": "ProductCodeGPKCodelijst"
          }
        }
      },
      {
        "id": "ImmunizationRecommendation.recommendation.vaccineCode.coding.HPK",
        "path": "ImmunizationRecommendation.recommendation.vaccineCode.coding",
        "sliceName": "ProductCodeHPKCodelijst",
        "max": "1",
        "binding": {
          "strength": "extensible",
          "description": "ProductCodeHPKCodelijst",
          "valueSetReference": {
            "reference": "http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.11.1.2--20150401000000",
            "display": "ProductCodeHPKCodelijst"
          }
        }
      },
      {
        "id": "ImmunizationRecommendation.recommendation.vaccineCode.coding.ZI",
        "path": "ImmunizationRecommendation.recommendation.vaccineCode.coding",
        "sliceName": "ProductCodeZICodelijst",
        "max": "1",
        "binding": {
          "strength": "extensible",
          "description": "ProductCodeZICodelijst",
          "valueSetReference": {
            "reference": "http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.11.1.6--20150401000000",
            "display": "ProductCodeZICodelijst"
          }
        }
      },
      {
        "id": "ImmunizationRecommendation.recommendation.vaccineCode.coding.ATC",
        "path": "ImmunizationRecommendation.recommendation.vaccineCode.coding",
        "sliceName": "ProductCodeATCCodelijst",
        "max": "1",
        "binding": {
          "strength": "extensible",
          "description": "ProductCodeATCCodelijst",
          "valueSetReference": {
            "reference": "http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.11.1.4--20150401000000",
            "display": "ProductCodeATCCodelijst"
          }
        }
      },
      {
        "id": "ImmunizationRecommendation.recommendation.vaccineCode.coding.PRK",
        "path": "ImmunizationRecommendation.recommendation.vaccineCode.coding",
        "sliceName": "ProductCodePRKCodelijst",
        "max": "1",
        "binding": {
          "strength": "extensible",
          "description": "ProductCodePRKCodelijst",
          "valueSetReference": {
            "reference": "http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.11.1.1--20150401000000",
            "display": "ProductCodePRKCodelijst"
          }
        }
      },
      {
        "id": "ImmunizationRecommendation.recommendation.vaccineCode.coding.GTIN",
        "path": "ImmunizationRecommendation.recommendation.vaccineCode.coding",
        "sliceName": "ProductCodeGTINCodelijst",
        "max": "1",
        "binding": {
          "strength": "extensible",
          "description": "ProductCodeGTINCodelijst",
          "valueSetReference": {
            "reference": "http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.11.1.5--20150401000000",
            "display": "ProductCodeGTINCodelijst"
          }
        }
      },
      {
        "id": "ImmunizationRecommendation.recommendation.dateCriterion",
        "path": "ImmunizationRecommendation.recommendation.dateCriterion",
        "short": "StartDate / EndDate",
        "comment": "This element can be used to capture the StartDate and EndDate concepts of the ZIB OverdrachtGeplandeZorgActiviteit.",
        "alias": [
          "StartDate",
          "EndDate"
        ],
        "mapping": [
          {
            "identity": "hcim-plannedcareactivityfortransfer-v1.2.1-2015EN",
            "map": "NL-CM:16.1.10",
            "comment": "StartDate"
          },
          {
            "identity": "hcim-plannedcareactivityfortransfer-v1.2.1-2015EN",
            "map": "NL-CM:16.1.11",
            "comment": "EndDate"
          }
        ]
      },
      {
        "id": "ImmunizationRecommendation.recommendation.protocol.authority",
        "path": "ImmunizationRecommendation.recommendation.protocol.authority",
        "type": [
          {
            "code": "Reference",
            "targetProfile": "http://fhir.nl/fhir/StructureDefinition/nl-core-organization"
          }
        ]
      },
      {
        "id": "ImmunizationRecommendation.recommendation.supportingImmunization",
        "path": "ImmunizationRecommendation.recommendation.supportingImmunization",
        "type": [
          {
            "code": "Reference",
            "targetProfile": "http://nictiz.nl/fhir/StructureDefinition/zib-Vaccination"
          }
        ]
      },
      {
        "id": "ImmunizationRecommendation.recommendation.supportingPatientInformation",
        "path": "ImmunizationRecommendation.recommendation.supportingPatientInformation",
        "type": [
          {
            "code": "Reference",
            "targetProfile": "http://nictiz.nl/fhir/StructureDefinition/zib-AllergyIntolerance"
          }
        ]
      }
    ]
  }
}